Whether you are an owner builder or building with a volume builder, the drawings you approve will usually mark every window with a code. A window code is the label printed beside each opening on the floor plan and the elevations. An elevation is a drawing of one outside wall, seen straight on.
A label might be a plain reference, such as W1 or W2, that just points you to the schedule. Or it might pack in a size, in numbers, and a window type, in letters.
Window makers don’t all number their windows the same way, and there is no numbering rule that every Australian maker follows. The same digits can mean different sizes on different makers’ charts.
Take a made-up code, 06-09. If the drawing’s legend says its codes give height then width in hundreds of millimetres, that window is about 600 mm high and 900 mm wide. If the legend says something else, so does the window. Read the legend, or the maker’s size chart it refers to, before you take a size from any code.
Even read correctly, a code leaves most of the window out. It doesn’t tell you the glass, the frame material or colour, the handles and locks, or which way the window opens.

A window schedule lists every window on the drawings by its label, one row per window.
Not every schedule carries every column. A schedule may include:
If a column you care about is missing, have it added. A blank cell can mean the decision hasn’t been made yet.
This made-up row, not a real job, shows how the columns read together.
| Label | Room | Size (H x W, mm) | Type and opening | Frame and glass | Head / sill (mm) |
|---|---|---|---|---|---|
| W4 | Kitchen | 1100 x 1800 | Sliding, left panel slides | uPVC, white, double glazed | 2100 / 1000 |
Read across and you know the kitchen window is 1100 mm high and 1800 mm wide, and slides open from the left. Its top sits 2100 mm up and its bottom 1000 mm up, clear of a bench built to about 900 mm.
The figures should agree: head height less window height gives roughly the sill height (2100 less 1100 is 1000). If a row is well out, ask the designer which is right.
If the frame column lists aluminium and you want to compare it with uPVC double glazed windows, raise it now, while the drawings can still change.

U-value measures how fast heat passes through the whole window, frame and glass together. A lower number means less heat lost on a winter night. SHGC, the solar heat gain coefficient, measures how much of the sun’s heat the window lets in. A lower SHGC means less heat gained on a summer afternoon.
For a new home, the energy assessment report, from the assessor who rated the design, should list each window type with its whole-window U-value and SHGC. Your schedule may repeat those figures or may not, so check them in the report.
Watch for a centre-of-glass figure. It leaves out the frame, so it can make a window look better than the whole unit performs.
The windows you order should match the figures the assessor modelled. What those figures need to add up to is covered in our guide to energy ratings for new Victorian homes.

Head height is the height of the top of a window. Sill height is the height of its bottom edge. Both are written in millimetres, in the schedule or on the elevations, measured from a level the drawings show.
Head heights are normally lined up with the other windows, or the door heads, on the same wall. That keeps the outside of the house looking deliberate. If one window on an elevation sits higher or lower than its neighbours, check that it was meant to.
Sill heights matter most where something sits below the window. A kitchen window has to clear the benchtop, and a servery window’s sill follows the bench height. Beside a bed or a desk, a low sill changes what can go against that wall.
These numbers can also bring in building code rules. How much window a room needs for natural light and fresh air is set by the code. Upstairs, a low bedroom sill can trigger fall protection, so check whether upstairs bedroom windows need a restrictor.
Glass close to the floor, and glass in or near doors and wet areas, can need safety glass under Part 8.4 of the ABCB Housing Provisions. Your designer confirms which windows that applies to.

Opening direction, sometimes called handing, tells you which side a window hinges or slides from, and whether it opens in or out. It is shown on the elevations as a drawn symbol, or written in the schedule. Symbols vary between drawing sets, so the legend explains what yours mean.
If a window has no opening direction marked anywhere, get it marked before anyone orders it.
Then picture each window open. An outward-opening sash shouldn’t swing into a path, a fence or a deck where people walk. A sash over a kitchen bench needs a handle or winder you can reach across the bench. A handle should sit on the side that suits how the room is used, not hard against a wall or a robe.
Screens need room too. An outward-opening window commonly takes its insect screen on the inside, so the screen has to leave the handle or winder usable. Our guide to which windows can take an insect screen covers each opening style.

Before the drawings are finalised, go through the schedule room by room:
If anything is wrong, ask the designer to correct the drawings. A note to the builder is easy to lose, and the drawings are the record everyone works from.

A change after the building permit is issued is possible, but it reaches further than the window itself.
The glazing was modelled in the energy assessment, so a different window can mean the house is re-assessed and the paperwork re-submitted. A wider opening in a load-bearing wall needs an engineer to size the beam above it, and a building permit for the work. In Victoria that permit comes from a registered building surveyor, private or through your council. Brickwork and cladding are set out around the openings, so a size change can mean rework on site. And a different window carries a different price.
The timing is set out in how long double glazed windows take to make and install, including when the order needs to go in.
If you are weighing up uPVC against the windows your builder has drawn, send the window schedule, or the plan and elevation pages, through the Weatherall Windows contact page. The form takes an uploaded file up to 10MB. Ask for the matching uPVC double glazed specification for each window on the list.
No. A code identifies the opening and, at best, its rough size and type. A maker also needs the glass, frame, colour, hardware and opening direction, which come from the schedule and elevations.
Treat it as a drawing error rather than something for the window supplier to guess. Have the designer confirm which one is right, and update both, before any order is placed.